ZCFQ8 explosion-proof safety emergency cut off solenoid valve technical parameters:

Product model: ZCFQ8-450MB

Size: DN1-1000mm

Principle structure: piston type

Working environment temperature: -10-+50℃ -40-+80℃

Coil operating temperature: <+50℃, <+85℃

Control mode: Normally open

Flow fluid pressure: 0.~1.6Mpa

Body material: cast steel, stainless steel 304, 316.

Applicable media: gas, oil, corrosive fluid.

Medium temperature: -20~+200℃.

Medium viscosity: less than 50CSt (more than 50 need to be customized).

Protection performance: waterproof, dustproof, explosion-proof (Exd IICT5), anti-corrosion.

Spool material: all stainless steel.

Wiring mode: socket type, lead type, plug type.

Power supply voltage: DC12, DC24V, DC36V, DC110V, DC127V, DC220V, DC380V;

AC24V, AC36, AC110V, AC127V, AC220V, AC380V.

Connection mode: flange, internal thread, external thread, sleeve

Leakage: zero



Please contact us if you need customized services. We will contact you with the price and availability in 24 hours.

Product Product Code Purity Size Contact Us
ZCFQ8 explosion-proof safety emergency cut off the solenoid valve,explosion-proof safety emergency cut off the solenoid valve,solenoid valve VF--DCCC-DC15-CU Customized Customized

ZCFQ8 explosion-proof safety emergency cut off solenoid valve features:

After the valve is closed, it will not open automatically after the power is turned on or off. It needs to be opened manually to keep it open, which is energy-saving and safe. Stainless steel spool, stable performance; Instant power, fast cut off; Zero leakage; Most suitable for use in explosive hazardous places.


How it works:

A: When the valve needs to be opened, unscrew the protective cover (there is a threaded hole in the middle of the protective cover, and turn it on the linkage rod to be used as the handle), and pull the handle hard to open the valve.

B: When the valve needs to be closed, the coil is energized for no more than 1 second, and the valve is quickly closed.


Industrial furnaces, gas pipe networks, gas treatment plants, gas stations, gas leak alarm systems, fire alarm systems and other urban or factory flammable and explosive media cut off; When the hidden danger of the accident is found, it is quickly cut off to prevent the occurrence of malignant accidents in time.

Packing of Standard Packing: 

Typical bulk packaging includes palletized plastic 5 gallon/25 kg. pails, fiber and steel drums to 1 ton super sacks in full container (FCL) or truck load (T/L) quantities. Research and sample quantities and hygroscopic, oxidizing or other air sensitive materials may be packaged under argon or vacuum. Solutions are packaged in polypropylene, plastic or glass jars up to palletized 470 gallon liquid totes Special package is available on request. E FORUs’  is carefully handled to minimize damage during storage and transportation and to preserve the quality of our products in their original condition.